LCMS - Cortisol & Cortisone in urine

Cortisol & Cortisone Urine LC-MS reagens kit (by SPE clean up)

SKU: 1040 KIT M CORT

The Cortisol & Cortisone reagents set from diagnotix • •• can determine the concentrations of both cortisol and cortisone in urine or saliva.

Advantages of the Diagnotix Cortisol & Cortisone LC-MS method:

  • 6-point calibrator based on Human urine like matrix
  • Internal standard with deuterium labeled cortisol and cortisone
  • Proper product clean-up using SPE-columns
  • Extremely sensitive, making it possible even the very low concentrations in saliva can be measured
  • The kit does not include SPE material, allowing you to purchase it directly from the manufacturer in your preferred format at the best price to meet your laboratory's specific requirements.

Intended use



The Diagnotix Cortisol & Cortisone LC-MS Kit is specifically designed to measure cortisol and cortisone concentrations in patient samples, providing a reliable foundation for further diagnostic evaluations.



Technical benefits


  1. Advanced Sample Preparation: Effectively removes contaminants and background compounds, ensuring high-quality data and cleaner analyses.
  2. Extended Column Lifespan: Reliable performance reduces the need for frequent replacements.
  3. Simplified Data Analysis: User-friendly workflows for efficient interpretation of results, due to low background noise.


Especially interesting for:


  • Laboratories processing high sample volumes on a weekly or daily basis.
  • Laboratories prioritizing clean LC-MS systems to minimize downtime and maintenance costs.
  • Facilities utilizing LC-MS systems for multiple methodologies, requiring robust and consistent performance every run.


Contact Us for More Information


Interested in learning more about our Cortisol&Cortisone analysis? Contact us via the contact form below. We looking forward to hear from you!

Contact form

Included in kit (200 assays):

  • 1042 CAL M CORT, Calibrator Set (Calibrator 1 – 6), 6 x 2 x 1 ml
  • 1049 M CORT, Internal Standard, 2 x 6 ml
  • 1051 M CORT, Mobile Phase I, 1 x 500 ml
  • 1052 M CORT, Mobile Phase II, 1 x 500 ml
  • 1053 M CORT, Washing Solution, 2 x 100 ml
  • 1058 M CORT, Conditiong Solution, 2 x 100 ml
  • 1050 M CORT, Elution Solution, 2 x 100 ml
  • 1057 M CORT, Reconstitution Solution, 1 x 100 ml
  • 10401 M CORT, Autosampler Washing Solution, 1 x 1000 ml

Clinical relevance

The ratio between cortisol and cortisone is of clinical importance with the diagnosis of Cushing syndrome. This even indicates apparent mineralocorticoid excess, a disease where the 11β-hydroxysteroid dehydrogenase-activity is weakened significantly or is even absent.

Chromatograms

Technical data

Interested in our products or services?
Contact us
or call us on +31 (0)596 20 10 62

More info?

* Mandatory fields

Contact us for more information about this product using the contact form or the contact information below.

Contact details

De Plassen 4
9902 SE Appingedam
The Netherlands

info@diagnotix.com +31 (0)596 20 10 62

Related products

Number of assays per kit 200
Matrix • Urine
• Saliva
Sample Preparation • Mix 10 sec. 300 μl sample + 50 μl Internal standard
• add ontp conditioned SPE-tube or SPE-well
• Was en elute from SPE
• Evaporate en reconstitute with reconstitution buffer
• Analyze onto LC-MS
Limit of Detection (LOD) • Cortisol: 0.2 nmol/l
• Cortisone: 0.2 nmol/l
Linearity • Cortisol: 1250 nmol/l
• Cortisone: 1680 nmol/l
Repeatability (CV%) • Cortisol Control low: 1.7
• Cortisol Control high: 1.0
• Cortisol Patient: 0.8
• Cortison Control low: 3.6
• Cortison Control high: 1.3
• Cortison Patient: 1.1
Reproducibility (CV%) • Cortisol Calibrator low: 3.70
• Cortisol Calibrator high: 4.82
• Cortisol Patient: 2.91
• Cortison Calibrator low: 3.36
• Cortison Calibrator high: 5.49
• Cortison Patient: 2.66
Injection volume 5 - 20 µl
Ionisation ESI Positive
Examples of LC-MS systems • Waters TQS-Micro or more sensitive
• Shimadzu 8050 or more sensitive
• Sciex 4500 of more sensitive